Basis of Issue Plan - BOIP
A. DESCRIPTION: THE ELECTRIC POWER PLANT CONSISTS OF TWO
150-KW GTED GENERATOR SETS, POWER DISTRIBUTION UNIT, CABLES, AND
ANCILLIARY EQUIPMENT.
B. CAPABILITIES: THE TRUCK TOWS A 600-GAL FUEL TANK MOUNTED
ON A MM353 3 1/2-TON TRAILER (LIN Z77520, BOIP 770212). POWER
CABLES ARE RUN TO THE RADAR AND ENGAGEMENT CONTROL STATION. A
MONITORING CABLE CONNECTS TO THE ENGAGEMENT CONTROL STATION WHERE
OPERATORS CAN OBSERVE LOW FUEL WARNINGS AND OPERATE A BATTLE
SHORT SWITCH FOR SHUT DOWN.
C. EMPLOYMENT: THE ELECTRIC POWER PLANT IS THE PRIME POWER
SOURCE FOR THE PATRIOT FIRE CONTROL SECTION EQUIPMENT (ENGAGEMENT
CONTROL STATION, LIN E08497; RADAR SET, LIN R18815; AND ANTENNA
MAST GROUP, LIN A80593).
D. BASIS OF ISSUE: ONE ELECTRIC POWER PLANT IS REQUIRED FOR
EACH PATRIOT FIRE CONTROL SECTION IN SRC 44637.
E. POWER REQUIREMENTS: THERE IS NO EXTERNAL POWER
REQUIREMENT.
F. TRANSPORTATION REQUIREMENTS: TRUCK MOUNTED ON M811 5-TON
CHASSIS.
G. PERSONNEL/MAINTENANCE IMPACTS:
(1) OPERATOR:
(A) CREW SIZE/MOS: OPERATOR IS DESIGNATED BY UNIT
COMMANDER PER 12-HOUR SHIFT.
(B) TRAINING REQUIREMENTS (MOS/GENERAL): THE
OPERATOR IS TRAINED AS A PATRIOT MISSILE CREWMEMBER (MOS 16T).
(2) MAINTAINERS:
(A) UNIT MAINTENANCE: MOS 52F FOR POWER PLANT AND
63B FOR WHEEL VEHICLE.
(B) IDS/IGS MAINTENANCE: MOS 52F FOR POWER PLANT AND
MOS 44B, 63G, AND 63W FOR WHEEL VEHICLE.
H. SPECIAL NOTES: THIS ITEM IS APPROPRIATE FOR
INCLUSION IN AR 71-13.